Deltadyne is a matched assembly, parts may not be purchased separately and are not necessarily interchangable. Non-resettable. Actuation pressure: 24 psid + or - 3 psi. System pressure: 100-120 psi; proof: 250 psi; burst: 400 psi. Temperature range: -65 to +300 degrees f. Fluid: lubricating oi (mil-l-7808, mil-l-23699). Once actuated the button remains in the actuated position until the indicator is inverted and manually depressed. Thermal lockout: a bimetal element is provided which prevents actuation below 125 degrees f, permits actuation above 155 degrees f. Has a red indicator button , extends 3/16" when actuated (annodized and dyed red) top surface of indicator button to be clear.
NSN 6150-00-596-9882
NSN 5965-00-275-0491
NSN 5905-01-521-3496
NSN 5985-00-863-7908
NSN 6240-01-381-8713
NSN 6145-00-405-9819
NSN 5945-01-634-0588
NSN 5945-00-805-2086
NSN 7035-01-184-8905
NSN 4140-01-195-2070
NSN 5925-01-510-2600
NSN 5835-00-725-2087